Ex Cable Gland Selection & Installation: Avoiding Common Pitfalls in Hazardous Zone 1/2 Applications

Ex Cable Gland Selection & Installation: Avoiding Common Pitfalls in Hazardous Zone 1/2 Applications

The integrity of electrical installations in oil and gas hazardous areas hinges on one critical component often overlooked: the cable gland. A single compromised seal or material mismatch can transform a cable entry point into an ignition source, with catastrophic consequences. In Zone 1 and 2 environments—where flammable gases or vapors may exist during normal operations or process upsets—the selection and installation of Ex-certified cable glands becomes a non-negotiable safety imperative. Industry data reveals that >40% of explosion protection failures originate from incorrect gland practices, making this a pivotal operational risk area.

Understanding Hazardous Area Cable Gland Types

Flameproof Glands (Ex d)

Engineered to contain internal explosions, Ex d glands prevent flame transmission to the external atmosphere. Their robust construction features:

  • Reinforced bodies with flame paths that cool escaping gases below ignition temperatures
  • Mandatory barrier sealing for cables lacking extruded bedding or compact circularity (e.g., unfilled multi-core cables)
  • Strict certification requirements (IEC 60079-1) prohibiting interchangeability with non-Ex d glands on flameproof equipment

Critical Application Note: Post-2024 IEC 60079-14 updates eliminated the 3-meter exemption—barrier glands are now compulsory for all Zone 1 Ex d installations regardless of cable length .

Increased Safety Glands (Ex e)

Designed to eliminate sparking and overheating through enhanced mechanical security:

  • Anti-tamper features prevent loosening under vibration (common in compressor stations)
  • IP66/IP68 sealing ensures dust/water ingress cannot cause short circuits
  • Thermal derating requirements for high ambient temperatures (>40°C)

Restricted Breathing Glands (Ex nR)

For Zone 2 applications where hazardous atmospheres are abnormal and short-lived:

  • Labyrinthine seals minimize gas ingress over time
  • Compatible with Ex d and Ex e equipment but require validation for cable length >3 meters

Gland Classification Reference Table:

Gland TypeSealing MechanismZone ApplicabilityKey Cable Compatibility
Ex d (Barrier)Resin/epoxy compound per conductorZone 1Non-circular, unfilled, hygroscopic filler cables
Ex eElastomeric outer sheath sealZone 1/2Circular, extruded bedding cables
Ex nRRestricted breathing labyrinthZone 2 onlyCompact cables >3m length

Material Compatibility: Beyond Corrosion Resistance

Metallurgical Considerations

  • Nickel-plated brass (10-12µm): Standard for most onshore applications; avoids spark risks. Ensure plating thickness exceeds IEC minimums (8µm) for H₂S resistance
  • 316L stainless steel: Mandatory for offshore/sour environments. Beware galvanic corrosion when mating with carbon steel enclosures—use dielectric washers
  • Aluminum hazards: Never pair brass glands with aluminum enclosures. Electrolytic reaction causes rapid degradation. Opt for anodized aluminum glands instead

Non-Metallic Innovations

  • Polycarbonate Ex e glands (e.g., blueglobe PC HT): Ideal for chemical exposure zones with -20°C to +60°C range
  • Silicone-sealed variants: Maintain elasticity from -60°C to +160°C for Arctic or furnace applications

Material Selection Checklist:
☐ Verify enclosure material (avoid Al/brass couples)
☐ Confirm operating temperature matches gland ratings
☐ Validate plating thickness >10µm for corrosive services
☐ Require IECEx/ATEX documentation for material traceability

Step-by-Step Installation Protocol

Preparation Phase

  1. Cable Verification: Confirm circularity with calipers. Reject cables with >5% ovality
  2. Sheath Stripping: Strip outer sheath per manufacturer’s length specification (typically 50mm). Critical error: Damaging armor or inner bedding
  3. Armor Treatment: Trim SWA/AWA to exact length. Use armor former tools to achieve smooth conical shape

Assembly Sequence

  1. Component Ordering: Thread components onto cable before termination. Missing the compression nut sequence is irreparable without cutting the cable
  2. Armor Clamping: For SWA cables, position armor wires uniformly under the cone. Overtightening deforms wires, reducing pullout strength by up to 70%
  3. Seat Inner Seal: For Ex e glands, lubricate elastomeric seals with silicone (never petroleum gel). Verify seal contacts inner bedding—not filler material

Torque Criticality

Gland Size (mm)Recommended Torque (Nm)Overtightening Effect
M2025-30Seal extrusion, loss of IP rating
M2530-35Sheath cracking, gas migration path
M3235-40Aluminum armor shearing
M4040-45Enclosure thread stripping

Always use calibrated torque wrenches—never adjust by “feel”

5 Catastrophic Errors and Their Remedies

1. Certification Mismatch

  • Error: Installing an Ex e gland on Ex d equipment, invalidating the flameproof rating
  • Solution: Match gland certification exactly to equipment protection type (Ex d gland for Ex d enclosure)

2. Barrier Gland Omission

  • Error: Assuming standard Ex d glands suffice for unfilled cables in Zone 1
  • Solution: Implement barrier glands for all Ex d entries unless using certified compact cables with extruded bedding

3. Ingress Protection Complacency

  • Error: Using generic washers instead of manufacturer-supplied IP sealing washers
  • Solution: Require glands with integrated OSTG (Overtightening Stop Technology) to prevent seal deformation

4. Cross-Zoning Misapplication

  • Error: Deploying Zone 2 (Ex nR) glands in Zone 1
  • Solution: Color-code installations by zone: light blue for intrinsically safe circuits, red tags for Zone 1 glands

5. Ignoring Dynamic Stresses

  • Error: Direct bending of cables <2.5cm from gland, causing terminal fractures
  • Solution: Maintain minimum 8x cable diameter bend radius and secure with cleats within 15cm of gland

Maintenance and Inspection Regimen

Quarterly Checks:

  • Torque verification (re-tighten to 80% initial value if >10% loss)
  • Seal integrity tests using dielectric grease to detect cracking
  • Continuity testing for armored cables (resistance <0.05Ω)

Post-Intervention Audits:
After any enclosure opening, conduct gas group re-verification—substituting glands rated for IIC (hydrogen) when original was IIB (ethylene) breaches Ex containment

The Future-Proof Installation

With IEC 60079-14:2024 raising the bar, oil and gas operators must:

  • Digitize gland records with IoT-enabled glands transmitting seal integrity data
  • Adopt lifecycle tracking via QR-coded certifications on every gland
  • Train installers on VR simulations of gas migration through faulty seals

“A cable gland is only as explosion-proof as its weakest seal. In hazardous areas, there is no room for approximation—only precision.” (IECEx Assessor Report, 2025)

By mastering gland selection criteria and installation rigor, oil and gas facilities transform cable entry points from vulnerability zones to fortified barriers against catastrophe. The marginal cost of premium-certified glands pales against the existential risk of compromise—a truth etched in every incident report from Piper Alpha to Deepwater Horizon.

Oil and Gas
oil and gas

Have Any Question?

If you have any questions, please contact us by sending an email to

zero@oil-gas.net