Convert gas flow rates between Sm³/d, Sm³/h, MMSm³/d, scf/d, Mscf/d, MMscf/d and Bscf/d.
Inputs
Results
Use a decimal point or decimal comma, with no thousands separators. Scientific notation (for example 1.5e-3) is accepted. Change any unit with the selector next to the value.
How it works
Enter a gas rate and its unit. Reference-condition correction is enabled by default: 1 MMscf/d is about 28 262 Sm³/d at 15 °C. Disable correction only for a geometric volume/time conversion: 1 million ft³/d = 28 316.85 m³/d. 10⁶ Sm³/d (MMSm³/d) means one million standard cubic metres per day.
Need actual flow at line pressure and temperature? Use the actual to standard gas flow converter.
Formulas
1 MMscf/d = 28 316.85 m³/d (volume units only) = 28 262 Sm³/d (at 15 °C) Sm³: 15 °C and 101.325 kPa · Nm³: 0 °C and 101.325 kPa · scf: 60 °F and 14.696 psia
Worked example
A gas field produces 10 MMscfd. What is that in Sm³/d at 15 °C?
- Geometric conversion: 10 × 10⁶ × 0.028 316 85 = 283 168 m³/d (still at 60 °F).
- Correct 60 °F to 15 °C: × 288.15 / 288.706 = × 0.998 08.
- Result: 282 625 Sm³/d.
Result: 282 625 Sm³/d (283 168 m³/d if no reference correction is applied).
Assumptions and limits
- Correction uses ideal-gas reference volumes: Sm³ at 15 °C/101.325 kPa, Nm³ at 0 °C/101.325 kPa and scf at 60 °F/14.696 psia. With correction disabled, all volumes are treated at the same reference conditions regardless of their labels. Verify the contractual reference conditions and compressibility basis before custody-transfer use.
Frequently asked questions
How many Sm³/d is 1 MMscfd?
About 28 262 Sm³/d at 15 °C (28 317 m³/d if you only convert cubic feet to cubic metres).
What is the difference between Sm³ and Nm³?
Sm³ is at 15 °C and Nm³ at 0 °C, both at 101.325 kPa. 1 Nm³ = 1.0549 Sm³.
What are the standard conditions for scf?
Usually 60 °F and 14.696 psia; US gas sales contracts often use 14.73 psia.
Why does the reference condition matter?
The 0.2-5 % differences add up to large money in custody transfer, and confuse plant balances when two units are mixed.
How do I get the actual flow at line conditions?
Use the actual to standard gas flow converter with pressure, temperature and Z.
References
- ISO 13443:1996, Natural gas - Standard reference conditions.
- GPSA Engineering Data Book, 14th ed. (2017), Section 1.
Related calculators
For education and quick estimates. Shared by the Oil-Gas.net Engineering Working Group as general practitioner guidance; not a standard and provided without warranty. Check every result against the governing standards, vendor data and your project or site requirements before design, operation or safety decisions.
Embed this tool on your site
Copy the code below into your page. The link to Oil-Gas.net must stay with the tool.
Calculator by Oil-Gas.net