Skip to content

Compressor power and discharge temperature calculator

Get a first estimate of the power a gas compressor needs and how hot the gas leaves each stage. Enter the gas flow, molecular weight, k and Z, the suction and discharge pressures, and an efficiency; choose the number of intercooled stages to see the effect of splitting the ratio.

Inputs

Results

Use a decimal point or decimal comma, with no thousands separators. Scientific notation (for example 1.5e-3) is accepted. Change any unit with the selector next to the value.

How it works

Give the flow at standard conditions (for example MMscfd or Sm³/h) or as mass flow, with the molecular weight, the ratio of specific heats k = cp/cv at suction and the average compressibility factor Z.

The overall pressure ratio is split equally between the stages, and the gas is assumed to be cooled back to the suction temperature before each stage with no pressure loss in the coolers. Each stage then has the same head and discharge temperature.

Choose a polytropic efficiency (usual for centrifugal compressors) or an isentropic efficiency (usual for reciprocating machines and quick estimates). Gas power is the head times mass flow divided by the efficiency; shaft power adds the mechanical losses.

Formulas

Stage pressure ratio:

r = (P2 / P1)^(1/N)

Isentropic head, discharge temperature and gas power:

H_s = (Z·R·T1 / M) · (k / (k−1)) · (r^((k−1)/k) − 1)
T2 = T1 · (1 + (r^((k−1)/k) − 1) / η_s)        P_gas = ṁ · H_s / η_s

Polytropic head, discharge temperature and gas power:

(n−1)/n = (k−1) / (k · η_p)
H_p = (Z·R·T1 / M) · (n / (n−1)) · (r^((n−1)/n) − 1)
T2 = T1 · r^((n−1)/n)        P_gas = ṁ · H_p / η_p

Shaft power and total:

P_shaft = N · P_gas,stage / η_mech

Symbols: P1, P2 = absolute suction and final discharge pressure; T1 = absolute suction temperature; N = number of stages; M = molar mass; R = 8.314 462 618 J/(mol·K); ṁ = mass flow; η_s, η_p = isentropic and polytropic efficiency; η_mech = mechanical efficiency.

Worked example

Boost 50 MMscfd of natural gas (MW 19, k 1.28, Z 0.95) from 30 bar(a) and 30 °C to 90 bar(a) with a centrifugal compressor of 78 % polytropic efficiency.

Inputs: Q = 50 MMscfd; M = 19 kg/kmol; k = 1.28; Z = 0.95; P1 = 30 bar(a); T1 = 30 °C; P2 = 90 bar(a); η_p = 78 %; η_mech = 98 %; 1 stage.

  1. Molar flow = 50 × 10⁶ scf/d / 836.62 scf per kmol / 24 h = 2490 kmol/h, so the mass flow is 2490 × 19 = 47 310 kg/h.
  2. (n−1)/n = 0.28 / (1.28 × 0.78) = 0.2804; ratio r = 3.
  3. H_p = (0.95 × 8.3145 × 303.15 / 0.019) / 0.2804 × (3^0.2804 − 1) = 162.2 kJ/kg.
  4. T2 = 303.15 × 3^0.2804 = 412.5 K = 139.4 °C.
  5. Gas power = 13.14 kg/s × 162.2 kJ/kg / 0.78 = 2732 kW; shaft power = 2732 / 0.98 = 2788 kW.

Result: About 2790 kW (3740 hp) shaft power, with the gas leaving at 139 °C.

Assumptions and limits

  • Ideal-gas equations with an average Z, and k taken as constant. For high pressures, heavy gases or ratios above about 3 per stage, use a process simulator or the Schultz method for real gases.
  • Equal pressure ratio per stage and perfect intercooling to the suction temperature, without cooler pressure drop or condensate removal. Real interstage losses add power.
  • Mechanical efficiency covers bearing, seal and gearbox losses; it does not include the driver (motor or turbine) efficiency.
  • This is a screening estimate. Final power comes from the compressor vendor's performance curves (API 617 for centrifugal and API 618 for reciprocating compressors).

Frequently asked questions

What is the difference between polytropic and isentropic efficiency?

Both compare the real compression with an ideal path. Isentropic efficiency compares it with a reversible adiabatic process; polytropic efficiency is defined over very small steps, so it does not depend on the pressure ratio. Centrifugal compressor vendors usually quote polytropic efficiency, typically 75-85 %.

How much power per MMscfd does a compressor need?

It depends strongly on the pressure ratio and the efficiency. For lean natural gas at 30 °C suction and 78 % polytropic efficiency, this calculator gives about 33 kW (45 hp) per MMscfd at a ratio of 2 and about 56 kW (75 hp) per MMscfd at a ratio of 3. Use the calculator for your own gas and conditions.

Why add stages?

Splitting the ratio with intercooling lowers the discharge temperature of each stage and the total power, because cooled gas is denser and easier to compress.

What k should I use for natural gas?

Lean natural gas has k of about 1.27-1.30 at suction conditions; heavier gases have lower values. Take k from your simulation at suction conditions.

Does the discharge temperature limit apply to centrifugal compressors?

API 618 sets 150 °C as the limit for reciprocating compressors. Centrifugal compressors have no fixed code limit, but seals, materials, coatings and downstream equipment often impose a similar limit.

References

  • API 617, Axial and Centrifugal Compressors and Expander-compressors, 9th ed. (2022).
  • API 618, Reciprocating Compressors for Petroleum, Chemical, and Gas Industry Services, 6th ed. (2024).
  • GPSA Engineering Data Book, 14th ed., Section 13 Compressors and Expanders.
  • Schultz, J. M., The polytropic analysis of centrifugal compressors, ASME Journal of Engineering for Power (1962).

For education and quick estimates. Shared by the Oil-Gas.net Engineering Working Group as general practitioner guidance; not a standard and provided without warranty. Check every result against the governing standards, vendor data and your project or site requirements before design, operation or safety decisions.

Embed this tool on your site

Copy the code below into your page. The link to Oil-Gas.net must stay with the tool.

Calculator by Oil-Gas.net