Enter the four terminal temperatures of a heat exchanger to get the log mean temperature difference, the F correction factor for shell-and-tube arrangements and the corrected mean temperature difference. Add the duty (or one stream's flow and heat capacity) and an overall heat transfer coefficient to get the area.
Inputs
Results
Use a decimal point or decimal comma, with no thousands separators. Scientific notation (for example 1.5e-3) is accepted. Change any unit with the selector next to the value.
How it works
Enter the hot fluid inlet and outlet and the cold fluid inlet and outlet temperatures, and choose the flow arrangement. For counter-current flow the terminal differences are hot inlet − cold outlet and hot outlet − cold inlet; for co-current flow they are the two inlet and the two outlet differences.
For shell-and-tube exchangers with one shell pass and two or more tube passes (TEMA E shell, "1-2"), the tool calculates the F correction factor from the temperature ratios P and R with the Bowman equation. For two shell passes in series ("2-4"), it first converts P to its one-shell value.
The duty can be entered directly or calculated from the mass flow and specific heat of the hot or cold stream. With an overall heat transfer coefficient U, the required area is Q / (U · F · LMTD).
Formulas
Log mean temperature difference:
LMTD = (ΔT1 − ΔT2) / ln(ΔT1 / ΔT2) (LMTD = ΔT1 when ΔT1 = ΔT2)
Temperature ratios:
R = (Th,in − Th,out) / (Tc,out − Tc,in) P = (Tc,out − Tc,in) / (Th,in − Tc,in)
F factor, 1 shell pass, 2 or more tube passes (Bowman, R ≠ 1):
F = [√(R²+1) / (R−1)] · ln[(1−P)/(1−P·R)] / ln{[2 − P(R+1−√(R²+1))] / [2 − P(R+1+√(R²+1))]}
N shells in series (P of one shell):
X = [(1−P·R)/(1−P)]^(1/N), P1 = (X − 1)/(X − R); for R = 1: P1 = P / (N − (N−1)·P)
Duty and area:
Q = ṁ · cp · ΔT A = Q / (U · F · LMTD)
Symbols: Th, Tc = hot and cold fluid temperatures; P = thermal effectiveness of the cold side; R = heat capacity rate ratio; U = overall heat transfer coefficient (including fouling).
Worked example
A 1-2 shell-and-tube exchanger cools 30 000 kg/h of oil (cp 2.2 kJ/kg·K) from 150 °C to 90 °C with cooling water heated from 30 °C to 80 °C. U = 350 W/m²·K. What area is needed?
Inputs: Th: 150 → 90 °C; Tc: 30 → 80 °C; 1 shell pass, 2 tube passes; ṁ = 30 000 kg/h, cp = 2.2 kJ/(kg·K) (hot side); U = 350 W/(m²·K).
- ΔT1 = 150 − 80 = 70 °C, ΔT2 = 90 − 30 = 60 °C, LMTD = (70 − 60) / ln(70/60) = 64.87 °C.
- R = 60 / 50 = 1.2, P = 50 / 120 = 0.4167, F = 0.8669.
- Q = 30 000/3600 × 2.2 × 60 = 1100 kW.
- A = 1 100 000 / (350 × 0.8669 × 64.87) = 55.88 m².
Result: F = 0.867, corrected MTD 56.24 °C and an area of about 55.9 m² (before any design margin).
Assumptions and limits
- Constant specific heats and constant U along the exchanger, no phase change in the corrected arrangements, and no heat loss to the surroundings.
- F applies to TEMA E shells with one or two shell passes and an even number of tube passes. Other shells (F, G, H, J, X) and cross-flow exchangers need their own F charts.
- Below about F = 0.8 the design is sensitive to small changes in temperatures and flows; TEMA practice is to add shells in series rather than design at low F.
- For condensing or boiling services, the LMTD is valid only if the condensing or boiling temperature is constant; otherwise zone the exchanger.
Frequently asked questions
What is a good F correction factor?
Designers usually aim for F of 0.8 or more. Lower values mean a large share of the area works against a small temperature difference and the exchanger is sensitive to fouling and flow changes; adding a shell in series raises F.
Why is co-current LMTD lower than counter-current?
In co-current flow the two fluids leave at nearly the same temperature, so the driving force falls along the length. Counter-current flow keeps a more even temperature difference and needs less area.
What is a temperature cross?
A temperature cross occurs when the cold fluid outlet is hotter than the hot fluid outlet. A single 1-2 shell can handle only a small cross; larger crosses need shells in series or a true counter-current exchanger.
Does it matter which fluid is on the shell side?
Not for the F factor of a 1-2 exchanger, which is the same whichever fluid is in the shell. It matters for fouling, pressure drop, cleaning and U.
Can I use the arithmetic mean instead of LMTD?
Only when the two terminal differences are close: within a ratio of about 1.5 the arithmetic mean is within 1.5 % of the LMTD.
References
- Bowman, R. A., Mueller, A. C. and Nagle, W. M., Mean temperature difference in design, Transactions of the ASME 62 (1940) 283-294.
- TEMA Standards, 10th ed. (2019), Section 7 (Thermal relations).
- Kern, D. Q., Process Heat Transfer, McGraw-Hill (1950).
- GPSA Engineering Data Book, 14th ed., Section 9 Heat Exchangers.
Related calculators
For education and quick estimates. Shared by the Oil-Gas.net Engineering Working Group as general practitioner guidance; not a standard and provided without warranty. Check every result against the governing standards, vendor data and your project or site requirements before design, operation or safety decisions.