Skip to content

Pump affinity laws calculator (speed and impeller diameter)

Use the affinity laws to see how a centrifugal pump's duty point moves when you change its speed with a variable-speed drive or trim its impeller. You can also work backwards: find the speed or impeller diameter that gives a target flow or a target head.

Inputs

Results

Use a decimal point or decimal comma, with no thousands separators. Scientific notation (for example 1.5e-3) is accepted. Change any unit with the selector next to the value.

How it works

Enter a known duty point on the pump curve: flow, head and, if you have them, power and NPSHr. Then choose whether you change the speed or the impeller diameter, and what you want to do.

Flow changes with the ratio of speeds (or diameters), head with the square of the ratio and power with the cube. NPSHr is scaled with the square of the speed ratio as a first estimate.

To find the speed or diameter for a target, the tool solves the same laws backwards: for a target flow the ratio is Q2/Q1, for a target head it is √(H2/H1). Note that this moves the point along a parabola through the origin; it gives the new point on the pump curve, not the intersection with your system curve.

Formulas

Affinity laws (x = N2/N1 for a speed change, x = D2/D1 for an impeller trim):

Q2 = Q1 · x        H2 = H1 · x²        P2 = P1 · x³

NPSH required (speed change, first estimate):

NPSHr2 ≈ NPSHr1 · (N2/N1)²

Ratio for a target:

x = Q_target / Q1        or        x = √(H_target / H1)

Symbols: Q = flow; H = head; P = shaft power; N = speed; D = impeller diameter.

Worked example

A pump delivers 200 m³/h at 80 m head and absorbs 60 kW at 2980 rpm; NPSHr is 4.0 m. What does it do at 2500 rpm on a variable-speed drive?

Inputs: Q1 = 200 m³/h; H1 = 80 m; P1 = 60 kW; NPSHr = 4.0 m; N1 = 2980 rpm; N2 = 2500 rpm.

  1. Ratio x = 2500 / 2980 = 0.8389.
  2. Q2 = 200 × 0.8389 = 167.8 m³/h.
  3. H2 = 80 × 0.8389² = 56.3 m.
  4. P2 = 60 × 0.8389³ = 35.43 kW.
  5. NPSHr2 ≈ 4.0 × 0.8389² = 2.82 m.

Result: About 167.8 m³/h at 56.3 m, using 35.4 kW (59 % of the original power).

Assumptions and limits

  • Efficiency is assumed unchanged. It stays close for moderate speed changes, but falls at low speeds and with larger impeller trims.
  • The impeller trim laws are approximate: they are reasonable for trims up to about 5-10 % of diameter; beyond that, ask the vendor for the trimmed curve.
  • The NPSHr scaling with the square of speed is an estimate; the exponent varies between pumps. NPSHr is not scaled for impeller trims.
  • The new point lies on the same system curve only if that curve is a parabola through the origin (pure friction, no static head). With static head, plot the system curve and find the intersection.

Frequently asked questions

How much power do I save by slowing a pump down?

Power falls with the cube of speed, so running at 80 % speed needs about 51 % of the power (0.8³). The real saving is smaller when the system has static head, because the pump must still overcome it.

Can I trim an impeller by 20 %?

Large trims are possible but the simple affinity laws become inaccurate and efficiency drops. Most pump vendors publish curves for a range of trims; use those for trims beyond about 10 %.

Why does the pump not reach the predicted flow after slowing down?

The affinity laws move the operating point along a parabola through zero. If your system has static head, the system curve does not pass through zero and the flow falls more than predicted.

Do the affinity laws apply to positive displacement pumps?

No. A positive displacement pump's flow is roughly proportional to speed, but its pressure is set by the system, not by speed squared.

What happens to NPSHr when I speed a pump up?

NPSHr rises roughly with the square of speed, so check the margin against NPSHa before increasing speed.

References

  • Karassik, I. J., Messina, J. P., Cooper, P. and Heald, C. C., Pump Handbook, 4th ed., McGraw-Hill (2008).
  • Gülich, J. F., Centrifugal Pumps, 4th ed., Springer (2020) - similarity laws and impeller trimming.
  • ANSI/HI 9.6.1-2017, Rotodynamic Pumps Guideline for NPSH Margin.

For education and quick estimates. Shared by the Oil-Gas.net Engineering Working Group as general practitioner guidance; not a standard and provided without warranty. Check every result against the governing standards, vendor data and your project or site requirements before design, operation or safety decisions.

Embed this tool on your site

Copy the code below into your page. The link to Oil-Gas.net must stay with the tool.

Calculator by Oil-Gas.net