After a kick is shut in, the first numbers on the kill sheet come from the shut-in drill pipe pressure: the formation pressure, the kill mud weight and the initial and final circulating pressures. This calculator gives them in seconds, together with the influx height and gradient and the MAASP at the shoe.
Inputs
Results
Use a decimal point or decimal comma, with no thousands separators. Scientific notation (for example 1.5e-3) is accepted. Change any unit with the selector next to the value.
How it works
Enter the true vertical depth of the bit (or of the influx zone), the original mud weight, the stabilised shut-in drill pipe pressure (SIDPP) and the slow circulating rate pressure (SCR) at the chosen kill pump rate.
The kill mud weight is the mud weight that balances formation pressure with no drill pipe pressure. The calculator rounds it up to the next 0.1 ppg (or 0.01 SG) and adds any trip margin you enter; ICP and FCP are then based on that rounded value, as on a standard kill sheet.
Optional: enter the shut-in casing pressure (SICP), pit gain and the annular capacity around the bottom-hole assembly to estimate the influx height and gradient, and the leak-off test result to get the MAASP before and after the kill.
Formulas
Formation pressure:
Pf = SIDPP + 0.052 × OMW × TVD
Kill mud weight:
KMW = OMW + SIDPP / (0.052 × TVD)
Initial and final circulating pressure:
ICP = SCR + SIDPP FCP = SCR × KMW / OMW
Influx height and gradient:
h = pit gain / annular capacity G_influx = G_mud − (SICP − SIDPP) / h
MAASP at the shoe:
MAASP = (EMW_LOT − MW) × 0.052 × TVD_shoe
Symbols: OMW = original mud weight (ppg); TVD in ft and pressures in psi in the oilfield form; SCR = slow circulating rate pressure at the kill rate; EMW_LOT = leak-off test result as equivalent mud weight.
Worked example
A kick is shut in at 10 000 ft TVD with 10.0 ppg mud. SIDPP = 520 psi, SICP = 800 psi, pit gain = 20 bbl, SCR = 600 psi at 30 spm. Annular capacity around the collars is 0.0291 bbl/ft; the shoe is at 5 000 ft TVD with a leak-off EMW of 14.0 ppg.
Inputs: TVD = 10 000 ft; OMW = 10.0 ppg; SIDPP = 520 psi; SICP = 800 psi; SCR = 600 psi; pit gain = 20 bbl; capacity = 0.0291 bbl/ft; shoe 5 000 ft, LOT 14.0 ppg.
- Formation pressure = 520 + 0.052 × 10.0 × 10 000 = 5720 psi.
- KMW = 10.0 + 520 / (0.052 × 10 000) = 11.0 ppg (already a whole 0.1 ppg step, so no rounding is needed).
- ICP = 600 + 520 = 1120 psi; FCP = 600 × 11.0 / 10.0 = 660 psi.
- Influx height = 20 / 0.0291 = 687.3 ft; gradient = 0.52 − (800 − 520) / 687.3 = 0.113 psi/ft, probably gas.
- MAASP = (14.0 − 10.0) × 0.052 × 5 000 = 1040 psi, falling to 780 psi once kill mud fills the annulus.
Result: Kill mud 11.0 ppg, ICP 1120 psi, FCP 660 psi; gas influx about 687 ft high; MAASP 1040 psi.
Assumptions and limits
- Vertical-well kill sheet. For deviated and horizontal wells the drill pipe pressure schedule from ICP to FCP must follow measured depth and TVD along the string; this tool gives only the end points.
- SIDPP must be stabilised and, with a float in the string, read correctly (bump the float).
- The influx is assumed to sit around the bottom-hole assembly in one annular capacity. Influx type from gradient is indicative only: gas below about 0.25 psi/ft, oil or mixtures 0.25-0.40 psi/ft, water above about 0.40 psi/ft.
- Surface BOP. For subsea wells the choke line friction must also be taken into account.
- The oilfield constant 0.052 is used by default, as in IWCF and IADC kill sheets; choose the exact basis for SI calculations.
Frequently asked questions
Why is the kill mud weight rounded up?
Mud is weighted up in practical steps and must at least balance the formation pressure. Rounding up to the next 0.1 ppg (or 0.01 SG) gives a small overbalance once the well is full of kill mud.
Why does the FCP use the ratio KMW/OMW?
The circulating friction loss is roughly proportional to the mud density, so the slow circulating pressure measured with the old mud rises in that ratio when the string is full of kill mud.
Should I add a trip margin to the kill mud weight?
Company practice varies. Many kill the well with the exact rounded kill mud weight and add trip margin afterwards. Enter a margin only if your well control procedure requires it.
What does a negative influx gradient mean?
It usually means one of the inputs is wrong: pit gain read too low, annular capacity too high, or the pressures not yet stabilised.
Can I use this for the Wait and Weight method and the Driller's method?
Yes. Both use the same ICP, FCP and kill mud weight. In the Driller's method the first circulation is at ICP with the original mud and the second circulation brings in kill mud.
References
- IWCF Drilling Well Control formula sheet (surface BOP), current edition.
- API RP 59, Recommended Practice for Well Control Operations, 2nd ed. (2006, reaffirmed 2023).
- IADC Drilling Manual, 12th ed. (2015), Well control chapter.
- Grace, R. D., Blowout and Well Control Handbook, 2nd ed., Gulf Professional Publishing (2017).
Related calculators
For education and quick estimates. Shared by the Oil-Gas.net Engineering Working Group as general practitioner guidance; not a standard and provided without warranty. Check every result against the governing standards, vendor data and your project or site requirements before design, operation or safety decisions.
Embed this tool on your site
Copy the code below into your page. The link to Oil-Gas.net must stay with the tool.
Calculator by Oil-Gas.net