Calculate the minimum wall thickness of straight process pipe under internal pressure to ASME B31.3, add the corrosion allowance and the mill under-tolerance, and find the lightest ASME B36.10 schedule that meets it. The tool also gives the maximum allowable working pressure of the selected schedule.
Inputs
Results
Use a decimal point or decimal comma, with no thousands separators. Scientific notation (for example 1.5e-3) is accepted. Change any unit with the selector next to the value.
How it works
Enter the internal design pressure, the pipe size (or a custom outside diameter), the basic allowable stress S of your material at the design temperature from ASME B31.3 Table A-1, and the quality factor E, the weld joint strength reduction factor W and the coefficient Y.
The tool calculates the pressure design thickness t, adds the mechanical, corrosion and erosion allowances c to get the minimum required thickness tm, and divides by (1 − mill tolerance) to get the minimum nominal wall thickness that can be ordered.
It then searches the ASME B36.10 schedules for the selected size and returns the lightest one whose wall, after mill tolerance, still meets tm, together with its MAWP. You can also check any nominal wall thickness you enter.
Formulas
Pressure design thickness, ASME B31.3 para. 304.1.2, eq. (3a), valid for t < D/6:
t = P · D / (2 · (S · E · W + P · Y))
Minimum required thickness and minimum nominal thickness:
tm = t + c t_nom ≥ tm / (1 − MT/100)
Maximum allowable working pressure of a nominal wall T_nom:
T = T_nom · (1 − MT/100) − c MAWP = 2 · S · E · W · T / (D − 2 · Y · T)
Symbols: P = internal design gauge pressure; D = outside diameter; S = basic allowable stress at design temperature (Table A-1); E = quality factor (Table A-1A / A-1B); W = weld joint strength reduction factor (para. 302.3.5); Y = coefficient from Table 304.1.1; c = sum of mechanical, corrosion and erosion allowances; MT = mill under-tolerance, %.
Worked example
Size the wall of an NPS 6 (DN 150) carbon steel line, ASTM A106 Grade B, for 50 bar(g) at a design temperature where S = 137.9 MPa, with a 3 mm corrosion allowance.
Inputs: P = 50 bar = 5.0 MPa; D = 168.28 mm; S = 137.9 MPa; E = 1.0 (seamless); W = 1.0; Y = 0.4; c = 3 mm; mill tolerance 12.5 %.
- t = 5.0 × 168.28 / (2 × (137.9 × 1.0 × 1.0 + 5.0 × 0.4)) = 3.007 mm.
- tm = 3.007 + 3 = 6.007 mm.
- Minimum nominal wall = 6.007 / (1 − 0.125) = 6.865 mm.
- Lightest schedule: Sch 40 / STD with 7.11 mm nominal (6.221 mm after mill tolerance).
- MAWP of Sch 40 / STD with c = 3 mm: 53.62 bar(g).
Result: Sch 40 / STD (7.11 mm) is the lightest schedule; its MAWP is 53.62 bar(g).
Assumptions and limits
- Straight pipe under internal pressure only. Bends, branches, external pressure, sustained and occasional loads (weight, thermal expansion, wind, seismic) must be checked separately.
- You supply S from ASME B31.3 Table A-1 for your material and design temperature; the code tables are not reproduced here.
- Y = 0.4 applies to ferritic steels up to 482 °C (900 °F) and austenitic steels up to 566 °C (1050 °F); see Table 304.1.1 for other materials and temperatures.
- The mill under-tolerance of 12.5 % is the usual value for ASTM A106, A53 and A333 pipe; check your pipe specification.
- Schedule wall thicknesses are ASME B36.10 nominal values, converted from inches and rounded to 0.01 mm. Stainless pipe to ASME B36.19 (Sch 5S, 10S, 40S, 80S) is not listed.
- When t ≥ D/6 or P/(SE) > 0.385, the code requires special consideration of failure theory, fatigue and thermal stress (para. 304.1.2(b)); the tool warns but still shows the result.
Frequently asked questions
What is the difference between t, tm and the nominal thickness?
t is the thickness needed for pressure alone; tm adds the corrosion, erosion and thread or groove allowances; the nominal (ordered) thickness must still be at least tm after the mill under-tolerance has been taken off.
Where do I find the allowable stress S?
In ASME B31.3 Table A-1 (or Table A-1M in SI) for your material specification and grade at the design temperature. For example, ASTM A106 Grade B has 20.0 ksi (137.9 MPa) up to about 204 °C in recent editions; always confirm with your edition of the code.
What value of E should I use?
E = 1.0 for seamless pipe. Welded pipe has a lower quality factor, for example 0.85 for electric-resistance-welded pipe, unless additional examination raises it. Table A-1B lists E for each specification.
Why does the result change with the schedule but the formula uses outside diameter?
Equation (3a) is written with the outside diameter D, which is fixed for a nominal size, so the required thickness does not depend on the schedule. The schedule only decides whether the ordered wall is thick enough.
Does this replace a piping stress analysis?
No. It covers the pressure design of straight pipe only. Supports, thermal expansion, weight and occasional loads need a flexibility and stress analysis.
References
- ASME B31.3-2024, Process Piping, para. 304.1.1, 304.1.2 and Table 304.1.1; Appendix A tables for S and E.
- ASME B36.10-2022, Welded and Seamless Wrought Steel Pipe (wall thicknesses; formerly B36.10M).
- ASTM A106/A106M-19a, Seamless Carbon Steel Pipe for High-Temperature Service (mill tolerance 12.5 %).
Related calculators
For education and quick estimates. Shared by the Oil-Gas.net Engineering Working Group as general practitioner guidance; not a standard and provided without warranty. Check every result against the governing standards, vendor data and your project or site requirements before design, operation or safety decisions.
Embed this tool on your site
Copy the code below into your page. The link to Oil-Gas.net must stay with the tool.
Calculator by Oil-Gas.net